Shandong Gamma Gas Engineering Co. Ltd.

Products

Home > Products > Cabinet Nitrogen Generator > Lab Use Nitrogen Generator > Lab Use Convenient High Quality Small Nitrogen Generator

Lab Use Convenient High Quality Small Nitrogen Generator

Payment Type:
L/C,T/T
Incoterm:
FOB,CFR,CIF,FCA,CPT
Min. Order:
1 Set/Sets
Transportation:
Ocean,Land,Air
Port:
Qingdao,Tianjin,Shanghai
Share:
  • Product Description
Overview
Product Attributes

BrandGamma Gas

UsageNitrogen

PurposeGas separation

Application FieldsChemical

Noise LevelUltra Low

Machine SizeSmall

ConditionNew

CertificationCSA

TechnologyPressure Swing Adsorption

Supply Ability & Additional Information

PackagingCarton on pallet

Productivity20 pcs per month

TransportationOcean,Land,Air

Place of OriginChina

Supply Ability20 pcs per month

CertificateCE certification

PortQingdao,Tianjin,Shanghai

Payment TypeL/C,T/T

IncotermFOB,CFR,CIF,FCA,CPT

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Carton on pallet

Lab Use Convenient High Quality Small Nitrogen Generator is one kind of lab use small nitrogen generator with convenient operation and high quality.This Lab Use Nitrogen Generator use PSA(pressure swing adsorption) technologies, obtain nitrogen from air by using Air Compressor.It has compact structure with wheels at bottom. With a simple touch on start button, the machine starts to run. This small nitrogen generator is suitable for many lab analysis applications.

Reliable Lab Nitrogen Generator


1 Lab use convenient high quality nitrogen generator specification:

Item

Specification

Data

Remarks

1

Nitrogen purity

≥99.5%

Oxygen content ≤0.5%

2

Nitrogen flow rate

≥25 L/min

20℃, 101.325Kpa

3

Nitrogen outlet pressure

≥450-620 kPa

See note

4

Power supply

24V

DC

5

Start up time

≤15 minutes

Time to get 99.5% purity

6

Certificates

CE, CSA

customer's property, not distributable

7

Noise

≤72 Db(A)

One meter from equipment

8

Weight

≤160 Kg

With package

9

Dimension

850 x920 x 1100 mm

With package

10

Package

1 carton on 1 plywood pallet

 


2 Lab Use Nitrogen Generator Technical Specification

2.1 Compressed air consumption

The generator consumes a maximum of 115 slpm of compressed air to generate the required N2 flow. Air source is not included in this product.

2.2. Air supply pressure

Minimum air supply pressure shall be externally regulated to 600 kPa.  

2.3. Air quality

This Generator is provided with one full set of FESTO filters, the air supplied to the Generator still need to be dry and oil-free.

2.4. N2 output

2.4.1. Quantity of N2 generate: the generator is capable of deliver 25 slpm nitrogen.

2.4.2. Delivery pressure: the generator delivers N2 at a pressure greater than 450 kPa.  

2.4.3. O2 contamination level: O2 level in the N2 stream is not exceed 0.5%, and does not vary from peak to trough by more than 5% of the absolute concentration. 

2.5 Dimensions

With package, the Generator size: 850 mm (Length)x 920 mm (width)x 1100 mm(height).  

2.6 Weight

With package, the Generator weight is less than 160 kg.

2.7 Wheels

The Generator is fitted with 2 fixed wheels at the rear and 2 swivel wheels with brakes at the front

2.8 Connection to power supply

The Generator has a panel mounted connector on the rear panel

• Current capacity at maximum temperature 2.5A

• Jack plug, 5.5 x 2.5 x 9.5 mm, positive on the centre pin

• Maximum operating voltage at maximum temperature 30VDC.  

• Minimum number of insertions/extractions while maintaining contact resistance specification AND without mechanical failure: > 5000  

• Maximum contact resistance after specified minimum insertions: 30milliohms maximum  

• Insulation resistance: min 100MegaOhms after environmental and durability tests  

• Dielectric withstand Voltage : Min 500V for 60s

• Operating temperature range: -20 deg C to +70 deg C   

2.9 Indicator

The Generator has a pushbutton illuminated switch on the front panel

• Button to be flush mounting or recessed into a bezel to avoid damage

• High corrosion resistance, either plastic or stainless steel body  

• No symbol on button

• Size of button and bezel to be ~ 22mm to 30mm

• Mechanical Endurance : > 1000000 activations without mechanical failure

• Electrical Endurance : > 100000 cycles at maximum current and maintaining maximum specified contact resistance• Action mechanism : push on – push off

• Current handling capability : 4A DC min break, 4A DC min Make, inductive load (double the maximum expected current demand to give good lifetime)

• Maximum DC Working voltage : at least 40V DC

• Illumination type and color : LED, green

• Illumination Operating voltage: 24VDC

• Operating Temperature Range: -20deg C to +70 degC

• Terminal type : either screw terminal or 6.5mm spade type terminals  

2.10. Solenoids

The solenoids on the gas control valves is 24 VDC.

2.11. Operation

2.11.1. Operating cycle

A typical operating cycle for the Generator is 1 start per day and then run for 8 hours per day, which is equivalent to 2000 hours of operation per year. Depending upon the particular site, operating time could be anywhere between 0 and 24 hours per day.  

2.11.2. Operation at shutdown

When the power is turned off, the pressure vessels is maintained in the pressurized state by closing the two exhaust valves.  

2.12. Start up

12.1. Start up time

Start up times means the time from start up to producing qualified nitrogen.

The time to complete start up is less than 15 minutes.  

2.13. Gas connections

The two external gas connections on the Generator, Air In and N2 Out, are constructed from brass and are to suit ¼" (6.35 mm) OD tubing. There are labeling in English next to these connections, [Air In" and [N2 Out", as part of the rating label.

2.14. Environmental requirements

2.14.1. Operating temperatures

The Generator is normally operated within performance specification over the temperature range:

10ºC - 35ºC from 0 – 3000 m, and 10ºC - 25ºC from 3000 – 4500 m

The Generator can operate safely over the temperature range:

5ºC - 35ºC from 0 – 3000 m, and 5ºC - 25ºC from 3000 – 4500 m

2.14.2. Noise level requirements

Noise level from the Generator is less than 72dBa at 1m distance. This is achieved by fitting silencers on the exhaust vents.

2.15. Life Requirements

The Generator can operate with a mean time between failure of 5 years minimum. 


Product Categories : Cabinet Nitrogen Generator > Lab Use Nitrogen Generator

Home > Products > Cabinet Nitrogen Generator > Lab Use Nitrogen Generator > Lab Use Convenient High Quality Small Nitrogen Generator
Email to this supplier
  • *Subject:
  • *To:
    Mr. Eric Lee
  • *email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send